• Endotracheal Tube (Cuffed)

    20150-20916

    Autofusion Set


    Endotracheal Tube (Plain)

    20932-20939

    Novofusion Set

    •  Provided with soft cuff based on high volume and low pressure at the distal end
    •  Non-return valve with pilot cuff for easy assessment of the pressure in the main cuff
    •  Made of special thermo sensitive material readily conforming to body curvatures at body temperature

    Endotracheal tube sizes (I.D. of the tube in mm):

    Cuffed 3.5 4 4.5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10
    Plain 2 2.5 3 3.5 4 4.5 5 5.5

    Common Features

    •  Proximal end fitted with standard 15 mm connector
    •  Radiopaque line on the tube to facilitate easy location of tube
    •  Murphy eye at distal end for atraumatic intubation and extubation
  • Vial Access Spike
    Autofusion Set

    Polyspike

    Vial Access Spike

    13490-13496

    •  Vented spike for withdrawing fluids from vials or semi-rigid containers
    •  Reduces contamination through safety snap cap
    •  Available with green, blue & red color caps
    •  PVC free, DEHP free, Latex Free
    Polyspike Variants Fluid Filter Air Filter Nature of Use
    Polyspike R 0.1µ Chemotherapeutic Drugs
    Polyspike B 0.1µ Normal Drugs
    Polyspike G NA 0.1µ Normal Drugs
  • PROCEDURAL PACKAGES

    For implants
    in extreme safety

    All our devices
    can be provided
    with a product kit
    for the plant to ensure
    an extremely safe procedure


    • Double room with different light tubes
    • Differentiated diameters and heights for safe subcutaneous recognition of each chamber
    • Suitable for infusion of incompatible substances (e.g. risk of crystallization in case of mutual contact)
    • Large self-sealing silicone septum
    • Internal chamber in titanium to prevent the needle from affecting the bottom and to ensure the absence of interaction with the infused substances

    Features

    Chamber
    Material Titanio + Polisulfone
    Shape and size: base 50 mm x 34 mm
    Height: 13.9 mm – 15.4 mm
    Weight: 19.7 g
    Internal volume: 0.53 ml – 0.52 ml

    Catheter with rounded tip, dot marking every centimeter and number every 5 centimeters.

    Septum
    Material Silicone
    Available diameter for punctures *: 12.7 mm
    Maximum number of stings: 2000 with Huber needle from 22GA
    1000 with Huber needle from 19GA
    * For each septum

    Standard

    Code
    Catheter
    ø int
    mm
    ø ext
    mm
    ø ext
    mm

    lenght
    FR

    Volume
    ml

    201.21.10.91
    Silicone to double lumen
    small 1.0
    big 1.3
    3.4
    10.5
    600
    small 0.61
    big 1.3
    Kit Contents
    Chamber
    Catheter
    Connector
    Huber’s needle  22GA x 25.4 mm
    Luer Connector
    Code
    Item
    description
    POWER TI
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introducer
    Dimension
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.15.12.21
    All-in-One
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    12
    201.15.12.31
    All-in-One
    10.2
    8.5
    silicone
    1.50
    2.70
    8
    780
    9
    10
    18
    201.15.12.41
    All-in-One
    10.2
    8.5
    PUR
    1.10
    1.70
    5
    780
    5
    8
    13
    201.15.10.21
    Standard
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    12
    201.15.10.31
    Standard
    10.2
    8.5
    silicone
    1.50
    2.70
    8
    780
    NA
    10
    18
    201.15.10.41
    Standard
    10.2
    8.5
    PUR
    1.10
    1.70
    6,5
    780
    NA
    8
    13
    All-in-One  Kit Contens
    Chamber
    Catheter
    Connector
    Huber’s needle 22GA x 25.4 mm
    Luer’s connector
    Introductor-dilatator peel-away
    Introducer needle of 18GA
    Guide of “J” from 0.89 mm
    Tunneler in stainless steel

    Venous introduction set

    Code Colour Code
    201.51.10.91 Introduction set 11 FR
    10
    • Introducer-dilator peel-away
    • Introducer needle from 18 GA
    • Guide to “J” of 0.89 mm
    • Tunneling in stainless steel
  • Spinal System

    • Small size
    • “Wedge” shape to facilitate insertion into the subcutaneous pocket
    • The large surface of the septum facilitates localization during skin palpation and reduces the risk of close punctures
    • Excellent stability of the needle due to the high compression of the septum allowed by the Titanium chamber
    • Titanium guarantees maximum reliability and mechanical stability

    Caratteristiche

    Chamber
    Material Titanio
    Shape and Dimension: Wedge – base 27.5 mm x 19 mm
    Height: 10.5 mm
    Weight: 10.5 g
    Interior Volume: 0.53 ml
    Septum
    Material Silicone
    Diameter available for stings: 12.8 mm
    Maximum number of stings: 2000 with Huber’s needle of 22GA
    1000 with huber’s needle of 129GA

    A 50 micron filter inside the chamber prevents clogging of the system due to small particles

    Code
    Catheter
     Chamber
    Ø int
    mm
    Ø ext
    mm
    Ø ext
    GA
    Lenght
    mm
    Volume
    ml
    201.17.10.61
    ETI
    Open toe PU
    0.5
    1.0
    19
    900
    0.18
    201.17.10.71
    ETI
    Closed toe PU
    and side holes
    0.5
    1.0
    19
    900
    0.18
    Kit Contents
    Chamber
    Catheter
    Connector
    Huber’s needle  22GA x 25.4 mm
    Needle to tip Tronca
    Tuohy’s needle 17GA x 80 mm
    Tunneller in stainless stell

    Arterial System

    • Small size
    • “Wedge” shape to falicitate insertion into the subcutaneous pocket
    • The large surface of the septum facilitates localization during skin palpation and reduces the risk of close punctures
    • Excellent stability of the needle due to the high compression of the septum allowed by the Titanium chamber
    • Titanium guarantess maximum realibility and nechanical stability

    Features

    Chamber
    Material Titanio
    Shape and size: Wedge – base 27.5 mm x 19 mm
    Height: 10.5 mm
    Weight: 10.5 g
    Interior volume: 0.53 ml
    Septum
    Material Silicone
    Available dimater for punctures
    12.8 mm
    Maximum number of stings: 2000 with Huber’s needle of 22GA
    1000 with Huber’s needle of 129GA
    Code
    Chamber
    Catheter
    mm
    Ø int
    mm
    Ø ext
    mm
    Ø ext
    GA
    Lenght
    mm
    Volume
    ml
    201.17.10.51
    ETI
    Silicone
    1.0
    2.1
    6.5
    780
    0.61
    Kit contents
    Chamber
    Catheter
    Connector
    Huber’s needle  22GA x 25.4 mm
    Luer’s connector
    • Small size
    • “Wedge” shape to facilitate insertion into the subcutaneous pocket
    • Large septal surface facilitates localization during skin palpation and reduces the risk of close punctures
    • Excellent needle stability due to the high septal compression enabled by the Titanium chamber
    • Titanium ensures maximum mechanical reliability and stability

    Details

    Chamber
    Material Titanium
    Shape and size: Wedge – base 27.5 mm x 19 mm
    Height: 10.5 mm
    Weight: 10.5 g
    Internal Volume: 0.53 ml
    Septum
    Material Silicone
    Diameter available for punctures: 12.8 mm
    Maximum number of punctures: 2000 with 22GA Huber’s needle
    1000 with 129GA Huber’s needle

    Catheter with rounded tip, marking with dot every centimeter and number every 5 centimeters.

    Code
    Description
    product
    ETI
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introducer
    Size
    Fr
    Scope
    mL/min
    22GA
    Scope
    mL/min
    19GA
    201.17.12.21
    All-in-One
    10.5
    10.5
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    13
    201.17.12.31
    All-in-One
    10.5
    10.5
    silicone
    1.50
    2.70
    8
    780
    9
    10
    18
    201.17.12.41
    All-in-One
    10.5
    10.5
    PUR
    1.10
    1.70
    5
    780
    5
    8
    13
    201.17.10.21
    Standard
    10.5
    10.5
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    13
    201.17.10.31
    Standard
    10.5
    10.5
    silicone
    1.50
    2.70
    8
    780
    NA
    10
    13
    201.17.10.41
    Standard
    10.5
    10.5
    PUR
    1.10
    1.70
    5
    780
    NA
    8
    13
    All-in-One Kit Contents
    Chamber
    Catheter
    Connector
    Huber 22GA x 25.4 mm needle
    Luer Connector
    Peel-away introducer-dilator
    18GA introducer needle
    0.89 mm “J” guide
    Stainless steel tunneler
    Standard Kit Contents
    Chamber
    Catheter
    Connector
    Huber 22GA x 25.4 mm needle
    Luer Connector

    Venous Introduction Set

    Code Colour Code
    201.51.10.21 Introduction set 6.5 FR
    10
    201.51.10.31 Introduction set 9 FR
    10
    201.51.10.41 Introduction set 5 FR
    10
    • Peel-away introducer-dilator
    • 18 GA introducer needle
    • 0.89 mm “J” guide
    • Stainless steel tunneling
    • Chamber designed to be used at high flows for injections of contrast media
    • “Low-Profile” chamber to facilitate insertion into the subcutaneous pocket and increase patient comfort
    • Emerging domed septum for immediate and safe subcutaneous retrieval
    • The large surface area of ​​the septum reduces the risk of close punctures
    • Transparent and radiopaque elastomeric connector: fast, safe and reversible connection of the catheter

    Caratteristiche

    Chamber
    Material Titanio
    Shape and size: Circular – diam. base. 25 mm
    Height: 10 mm
    Wheight: 10.3 g
    Internal Volume: 0.6 ml

    Catheter with rounded tip, dot marking every centimeter and number every 5 centimeters.

    Septum
    Material Silicone
    Diameter available for punctures: 12.8 mm
    Maximum number of stings: 2000 with Huber’s needle from 22GA
    1000 with Huber’s needle from 19GA

    Max Flow Rate: 5ml / s with Max pressure 300PSI, Max Viscosity 12cP

    Code
    Item
    description
    POWER LPT
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introductor
    Size
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.26.12.30
    All-in-One
    10
    10.3
    silicone
    1.30
    2.70
    8
    600
    9
    7
    21
    201.26.12.20
    All-in-One
    10
    10.3
    PUR
    1.35
    2.00
    6
    600
    6.5
    8
    22
    201.26.12.33
    All-in-One
    10
    10.3
    PUR
    1.60
    2.70
    8
    600
    9
    8
    24
    201.26.10.30
    Standard
    10
    10.3
    silicone
    1.30
    2.70
    8
    600
    NA
    7
    21
    201.26.10.20
    Standard
    10
    10.3
    PUR
    1.35
    2.00
    6
    600
    NA
    8
    22
    201.26.10.33
    Standard
    10
    10.3
    PUR
    1.60
    2.70
    8
    600
    NA
    8
    24
    All-in-One Kit content
    Chamber Needle truncated point
    Catheter Syringe 10 ml
    Coonector
    Huber’s needle 22GA x 25.4 mm Huber’s needle 90° – 20GA x1″ with extension (in dedicated packaging)
    Luer’s connector
    Introducer-dilator peel-away
    ntroducer needle from 18GA
    Guide at “J” da 0.89 mm
    Tunneller in stainless steel
    Standard Kit of content
    Chamber
    Catheter
    Connector
    Huber’s needle 22GA x 25.4 mm
    Luer’s connector

    Venous introduction set

    Code Colour Code
    201.51.10.21 Introduction Set 6.5 FR
    10
    201.51.10.31 Introduction Set 9 FR
    10
    • Introducer-dilator peel-away
    • Introducer needle from 18 GA
    • Guide at “J” da 0.89 mm
    • Tunneling in stainless steel
    • High profile
    • Chamber designed to be used at high flows for injections of contrast media
    • The large surface of the septum facilitates localization during skin palpation and reduces the risk of close punctures
    • Transparent and radiopaque elastomeric connector: fast, safe and reversible connection of the catheter

    Caratteristiche

    Chamber
    Material Titanio
    Shape and size: Wedge- diam. base. 22 mm x 26 mm
    Height: 13 mm
    Wheight: 12 g
    Internal Volume: 0.82 ml

    Catheter with rounded tip, dot marking every centimeter and number every 5 centimeters.

    Septum
    Material Silicone
    Diameter available for punctures: 13 mm
    Maximum number of stings: 2000 with Huber’s needle from 22GA
    1000 with Huber’s needle from 19GA

    Max Flow Rate: 5ml / s with Max pressure 300PSI, Max Viscosity 12cP

    Code
    Item
    description
    POWER TI
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introducer
    Dimension
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.23.12.30
    All-in-One
    13
    12
    silicone
    1.30
    2.70
    8
    600
    9
    7
    21
    201.23.12.20
    All-in-One
    13
    12
    PUR
    1.35
    2.00
    6
    600
    6.5
    8
    22
    201.23.12.33
    All-in-One
    13
    12
    PUR
    1.60
    2.70
    8
    600
    9
    8
    24
    201.23.10.30
    Standard
    13
    12
    silicone
    1.30
    2.70
    8
    600
    NA
    7
    21
    201.23.10.20
    Standard
    13
    12
    PUR
    1.35
    2.00
    6
    600
    NA
    8
    22
    201.23.10.33
    Standard
    13
    12
    PUR
    1.60
    2.70
    8
    600
    NA
    8
    24
    All-in-One Kit Contents
    Chamber
    Catheter
    Connector
    Huber’s needle 22GA x 25.4 mm
    Luer Connector
    Introducer-dilator peel-away
    Introducer needle from da 18GA
    Guide at “J” from 0.89 mm
    Tunneler in stainless steel
    Standard Kit Contents
    Chamber
    Catheter
    Connector
    Huber’s needle 22GA x 25.4 mm
    Luer

    Venous introduction set

    Code Colour Code
    201.51.10.21 Introduction Set 6.5 FR
    10
    201.51.10.31 Introduction Set 9 FR
    10
    • Introducer-dilator peel-away
    • Introductor needle da 18 GA
    • Guide at “J” from 0.89 mm
    • Tunneling in stainless steel
    • Small size
    • Circular shape for maximum chamber stability (low risk of overturning)
    • The large surface of the septum facilitates localization when palpating the skin and reduces the risk of close punctures
    • Excellent stability of the needle due to the high compression of the septum allowed by the Titanium chamber
    • Titanium guarantees maximum reliability and mechanical stability

    Details

    Chamber
    Material Titanio
    Shape and size circular – diam. base. 26 mm
    Height: 10.2 mm
    Weight: 8.5 g
    Internal volume : 0.53 ml

    Catheter with rounded tip, marking with dot every centimeter and number every 5 centimeters.

    Septum
    Material Silicone
    Diameter available for punctures: 12.8  mm
    Maximum number of stings: 2000 with Huber needle from 22GA
    1000 with Huber needle from 19GA
    Code
    Item
    description
    POWER TI
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Dimension
    Fr
    Lenght
    mm
    Introducer
    Dimension
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.15.12.21
    All-in-One
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    12
    201.15.12.31
    All-in-One
    10.2
    8.5
    silicone
    1.50
    2.70
    8
    780
    9
    10
    18
    201.15.12.41
    All-in-One
    10.2
    8.5
    PUR
    1.10
    1.70
    5
    780
    5
    8
    13
    201.15.10.21
    Standard
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    12
    201.15.10.31
    Standard
    10.2
    8.5
    silicone
    1.50
    2.70
    8
    780
    NA
    10
    18
    201.15.10.41
    Standard
    10.2
    8.5
    PUR
    1.10
    1.70
    6,5
    780
    NA
    8
    13
    All-in-One Kit Contents
    Chamber
    Catheter
    Connector
    Huber needle from 22GA x 25.4 mm
    Luer Connector
    Introducer-dilator peel-away
    Introducer needle from 18GA
    Guide at “J” from 0.89 mm
    Tunneler in stainless steel
    Standard Kit Contents 
    Chamber
    Catheter
    Connector
    Huber needle from 22GA x 25.4 mm
    Luer Coonector

    Venous introduction set

    Code Code Colour
    201.51.10.21 Introduction Set 6.5 FR
    10
    201.51.10.31 Introduction Set 9 FR
    10
    201.51.10.41 Introduction Set 5 FR
    10
    • Dilatator-Introducer peel-away
    • Introducer needle from 18 GA
    • Guide at “J” da 0.89 mm
    • Tunneling in stainless steel

    • Extremely small size
    • “Wedge” shape to facilitate insertion into the subcutaneous pocket
    • Large surface of the self-sealing septum (in relation to the size of the chamber)
    • Indicated for patients with “cosmetic” needs or pediatric patients
    • Excellent needle stability due to the high compression of the septum allowed by the Titanium chamber
    • Titanium guarantees maximum mechanical reliability and maximum stability

    Features

    Chamber
    Material Titanium
    Shape and Size: Wedge – base 21 mm x 16 mm
    Height: 8,6 mm
    Weight: 6 g
    Volume Interior: 0,2 ml
    Septum
    Material Silicone
    Diameter available for punctures: 9 mm
    Maximum number of stings: 1500 with needle of Huber da 22GA

    Catheter with rounded tip, dot marking every centimeter and number every 5 centimeters.

    Code
    Description
    item
    miniMAX
    Height
    mm
    Wheight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introducer
    Dimension
    Fr
    Flow
    mL/min
    22GA
    201.16.12.21
    All-in-One
    8.6
    6
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    201.16.12.41
    All-in-One
    8.6
    6
    PUR
    1.10
    1.70
    5
    780
    5
    8
    201.16.12.55
    All-in-One
    8.6
    6
    PUR
    1.10
    1.70
    5
    780
    5
    8
    201.16.10.21
    Standard
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    201.16.10.41
    Standard
    10.2
    8.5
    PUR
    1.10
    1.70
    5
    780
    NA
    8
    All-in-One Kit contents
    Camera
    Catheter
    Connector
    Huber needle 22GA x 25.4 mm
    Luer Connector
    Introducer-dilator
    Introcuder needle of 18GA
    Guide at “J” from 0.89 mm
    Tunneler in stainless steel
    Standard Kit Content
    Camera
    Catheter
    Connector
    Huber needle 22GA x 25.4 mm
    Luer connector

    venous introduction set

    Code Colour Code
    201.51.10.21 Set introduction 6.5 FR
    10
    201.51.10.41 Set introduction 5 FR
    10
    • Introducer-dilator peel-away
    • Introducer needle from 18 GA
    • Guide at “J” from 0.89 mm
    • Tunneling in stainless steel