• Woo

    This is the new….

    prova

    Woo

    I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

    prova

  • GAVeCeLT 2021 recommendations for the indication, implantation and management of venous access devices.
    Curated by Mauro Pittiruti and Giancarlo Scoppettuolo
    Raccomandazioni GAVeCeLT 2021
  • Endotracheal Tube (Cuffed)

    20150-20916

    Autofusion Set


    Endotracheal Tube (Plain)

    20932-20939

    Novofusion Set

    •  Provided with soft cuff based on high volume and low pressure at the distal end
    •  Non-return valve with pilot cuff for easy assessment of the pressure in the main cuff
    •  Made of special thermo sensitive material readily conforming to body curvatures at body temperature

    Endotracheal tube sizes (I.D. of the tube in mm):

    Cuffed 3.5 4 4.5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10
    Plain 2 2.5 3 3.5 4 4.5 5 5.5

    Common Features

    •  Proximal end fitted with standard 15 mm connector
    •  Radiopaque line on the tube to facilitate easy location of tube
    •  Murphy eye at distal end for atraumatic intubation and extubation
  • Vial Access Spike
    Autofusion Set

    Polyspike

    Vial Access Spike

    13490-13496

    •  Vented spike for withdrawing fluids from vials or semi-rigid containers
    •  Reduces contamination through safety snap cap
    •  Available with green, blue & red color caps
    •  PVC free, DEHP free, Latex Free
    Polyspike Variants Fluid Filter Air Filter Nature of Use
    Polyspike R 0.1µ Chemotherapeutic Drugs
    Polyspike B 0.1µ Normal Drugs
    Polyspike G NA 0.1µ Normal Drugs
  • Poly flex adva

    On / Off Switch

    Art-Can Safety

    Needle Safety Guard

    Nouvo Safety

    Art-Can Safety

    Safety Arterial Cannula

    13424-13425

    • Suitable for arterial pressure monitoring and serial arterial blood gas determinations
    • Sharp atraumatic needle bevel helps the procedure with minimal patient discomfort
    • Specially designed ON-OFF switch prevents backflow and exposure of blod to healthcare professional and provide safety from Air Embolism and contamination
    • Needle safety guard automatically covers the needle’s sharp bevel after withdrawal of needle from the hub, minimizing the risk of Needle Stick Injury
    • Available with FEP/PUR catheter
    • Sizes: 20G & 22G
  • PROCEDURAL PACKAGES

    For implants
    in extreme safety

    All our devices
    can be provided
    with a product kit
    for the plant to ensure
    an extremely safe procedure


    • Double room with different light tubes
    • Differentiated diameters and heights for safe subcutaneous recognition of each chamber
    • Suitable for infusion of incompatible substances (e.g. risk of crystallization in case of mutual contact)
    • Large self-sealing silicone septum
    • Internal chamber in titanium to prevent the needle from affecting the bottom and to ensure the absence of interaction with the infused substances

    Features

    Chamber
    Material Titanio + Polisulfone
    Shape and size: base 50 mm x 34 mm
    Height: 13.9 mm – 15.4 mm
    Weight: 19.7 g
    Internal volume: 0.53 ml – 0.52 ml

    Catheter with rounded tip, dot marking every centimeter and number every 5 centimeters.

    Septum
    Material Silicone
    Available diameter for punctures *: 12.7 mm
    Maximum number of stings: 2000 with Huber needle from 22GA
    1000 with Huber needle from 19GA
    * For each septum

    Standard

    Code
    Catheter
    ø int
    mm
    ø ext
    mm
    ø ext
    mm

    lenght
    FR

    Volume
    ml

    201.21.10.91
    Silicone to double lumen
    small 1.0
    big 1.3
    3.4
    10.5
    600
    small 0.61
    big 1.3
    Kit Contents
    Chamber
    Catheter
    Connector
    Huber’s needle  22GA x 25.4 mm
    Luer Connector
    Code
    Item
    description
    POWER TI
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introducer
    Dimension
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.15.12.21
    All-in-One
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    12
    201.15.12.31
    All-in-One
    10.2
    8.5
    silicone
    1.50
    2.70
    8
    780
    9
    10
    18
    201.15.12.41
    All-in-One
    10.2
    8.5
    PUR
    1.10
    1.70
    5
    780
    5
    8
    13
    201.15.10.21
    Standard
    10.2
    8.5
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    12
    201.15.10.31
    Standard
    10.2
    8.5
    silicone
    1.50
    2.70
    8
    780
    NA
    10
    18
    201.15.10.41
    Standard
    10.2
    8.5
    PUR
    1.10
    1.70
    6,5
    780
    NA
    8
    13
    All-in-One  Kit Contens
    Chamber
    Catheter
    Connector
    Huber’s needle 22GA x 25.4 mm
    Luer’s connector
    Introductor-dilatator peel-away
    Introducer needle of 18GA
    Guide of “J” from 0.89 mm
    Tunneler in stainless steel

    Venous introduction set

    Code Colour Code
    201.51.10.91 Introduction set 11 FR
    10
    • Introducer-dilator peel-away
    • Introducer needle from 18 GA
    • Guide to “J” of 0.89 mm
    • Tunneling in stainless steel
  • Spinal System

    • Small size
    • “Wedge” shape to facilitate insertion into the subcutaneous pocket
    • The large surface of the septum facilitates localization during skin palpation and reduces the risk of close punctures
    • Excellent stability of the needle due to the high compression of the septum allowed by the Titanium chamber
    • Titanium guarantees maximum reliability and mechanical stability

    Caratteristiche

    Chamber
    Material Titanio
    Shape and Dimension: Wedge – base 27.5 mm x 19 mm
    Height: 10.5 mm
    Weight: 10.5 g
    Interior Volume: 0.53 ml
    Septum
    Material Silicone
    Diameter available for stings: 12.8 mm
    Maximum number of stings: 2000 with Huber’s needle of 22GA
    1000 with huber’s needle of 129GA

    A 50 micron filter inside the chamber prevents clogging of the system due to small particles

    Code
    Catheter
     Chamber
    Ø int
    mm
    Ø ext
    mm
    Ø ext
    GA
    Lenght
    mm
    Volume
    ml
    201.17.10.61
    ETI
    Open toe PU
    0.5
    1.0
    19
    900
    0.18
    201.17.10.71
    ETI
    Closed toe PU
    and side holes
    0.5
    1.0
    19
    900
    0.18
    Kit Contents
    Chamber
    Catheter
    Connector
    Huber’s needle  22GA x 25.4 mm
    Needle to tip Tronca
    Tuohy’s needle 17GA x 80 mm
    Tunneller in stainless stell

    Arterial System

    • Small size
    • “Wedge” shape to falicitate insertion into the subcutaneous pocket
    • The large surface of the septum facilitates localization during skin palpation and reduces the risk of close punctures
    • Excellent stability of the needle due to the high compression of the septum allowed by the Titanium chamber
    • Titanium guarantess maximum realibility and nechanical stability

    Features

    Chamber
    Material Titanio
    Shape and size: Wedge – base 27.5 mm x 19 mm
    Height: 10.5 mm
    Weight: 10.5 g
    Interior volume: 0.53 ml
    Septum
    Material Silicone
    Available dimater for punctures
    12.8 mm
    Maximum number of stings: 2000 with Huber’s needle of 22GA
    1000 with Huber’s needle of 129GA
    Code
    Chamber
    Catheter
    mm
    Ø int
    mm
    Ø ext
    mm
    Ø ext
    GA
    Lenght
    mm
    Volume
    ml
    201.17.10.51
    ETI
    Silicone
    1.0
    2.1
    6.5
    780
    0.61
    Kit contents
    Chamber
    Catheter
    Connector
    Huber’s needle  22GA x 25.4 mm
    Luer’s connector
    • Dimensioni ridotte
    • Forma a “cuneo” per favorire l’inserimento nella tasca sottocutanea
    • L’ampia superfice del setto facilita la localizzazione durante la palpazione della pelle e riduce il rischio di punture ravvicinate
    • Ottima stabilità dell’ago per l’elevata compressione del setto consentita dalla camera di Titanio
    • Il Titanio garantisce la massima affidabilità meccanica e la massima stabilità

    Caratteristiche

    Camera
    Materiale Titanio
    Forma e dimensioni: Cuneo – base 27.5 mm x 19 mm
    Altezza: 10.5 mm
    Peso: 10.5 g
    Volume Interno: 0.53 ml
    Setto
    Materiale Silicone
    Diametro disponibile per le punture: 12.8 mm
    Massimo numero di punture: 2000 con ago di Huber da 22GA
    1000 con ago di Huber da 129GA

    Catetere con punta arrotondata, marcatura con punto ogni centimetro e numero ogni 5 centimetri.

    Codice
    Descrizione
    prodotto
    miniMAX
    Altezza
    mm
    Peso
    g
    Materiale
    ID
    mm
    OD
    mm
    Dimensione
    Fr
    Lunghezza
    mm
    Introduttore
    Dimensione
    Fr
    Portata
    mL/min
    22GA
    Portata
    mL/min
    19GA
    201.17.12.21
    All-in-One
    10.5
    10.5
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    13
    201.17.12.31
    All-in-One
    10.5
    10.5
    silicone
    1.50
    2.70
    8
    780
    9
    10
    18
    201.17.12.41
    All-in-One
    10.5
    10.5
    PUR
    1.10
    1.70
    5
    780
    5
    8
    13
    201.17.10.21
    Standard
    10.5
    10.5
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    13
    201.17.10.31
    Standard
    10.5
    10.5
    silicone
    1.50
    2.70
    8
    780
    NA
    10
    13
    201.17.10.41
    Standard
    10.5
    10.5
    PUR
    1.10
    1.70
    5
    780
    NA
    8
    13
    All-in-One Contenuto del Kit
    Camera
    Catetere
    Connettore
    Ago di Huber 22GA x 25.4 mm
    Connettore Luer
    Introduttore-dilatatore peel-away
    Ago introduttore da 18GA
    Guida a “J” da 0.89 mm
    Tunnellizzatore in acciaio inossidabile
    Standard Contenuto del Kit
    Camera
    Catetere
    Connettore
    Ago di Huber 22GA x 25.4 mm
    Connettore Luer

    Set di introduzione Venoso

    Codice Codice Colore
    201.51.10.21 Set d’introduzione 6.5 FR
    10
    201.51.10.31 Set d’introduzione 9 FR
    10
    201.51.10.41 Set d’introduzione 5 FR
    10
    • Introduttore-dilatatore peel-away
    • Ago introduttore da 18 GA
    • Guida a “J” da 0.89 mm
    • Tunnellizzazione in acciaio inossidabile
    • Chamber designed to be used at high flows for injections of contrast media
    • “Low-Profile” chamber to facilitate insertion into the subcutaneous pocket and increase patient comfort
    • Emerging domed septum for immediate and safe subcutaneous retrieval
    • The large surface area of ​​the septum reduces the risk of close punctures
    • Transparent and radiopaque elastomeric connector: fast, safe and reversible connection of the catheter

    Caratteristiche

    Chamber
    Material Titanio
    Shape and size: Circular – diam. base. 25 mm
    Height: 10 mm
    Wheight: 10.3 g
    Internal Volume: 0.6 ml

    Catheter with rounded tip, dot marking every centimeter and number every 5 centimeters.

    Septum
    Material Silicone
    Diameter available for punctures: 12.8 mm
    Maximum number of stings: 2000 with Huber’s needle from 22GA
    1000 with Huber’s needle from 19GA

    Max Flow Rate: 5ml / s with Max pressure 300PSI, Max Viscosity 12cP

    Code
    Item
    description
    POWER LPT
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introductor
    Size
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.26.12.30
    All-in-One
    10
    10.3
    silicone
    1.30
    2.70
    8
    600
    9
    7
    21
    201.26.12.20
    All-in-One
    10
    10.3
    PUR
    1.35
    2.00
    6
    600
    6.5
    8
    22
    201.26.12.33
    All-in-One
    10
    10.3
    PUR
    1.60
    2.70
    8
    600
    9
    8
    24
    201.26.10.30
    Standard
    10
    10.3
    silicone
    1.30
    2.70
    8
    600
    NA
    7
    21
    201.26.10.20
    Standard
    10
    10.3
    PUR
    1.35
    2.00
    6
    600
    NA
    8
    22
    201.26.10.33
    Standard
    10
    10.3
    PUR
    1.60
    2.70
    8
    600
    NA
    8
    24
    All-in-One Kit content
    Chamber Needle truncated point
    Catheter Syringe 10 ml
    Coonector
    Huber’s needle 22GA x 25.4 mm Huber’s needle 90° – 20GA x1″ with extension (in dedicated packaging)
    Luer’s connector
    Introducer-dilator peel-away
    ntroducer needle from 18GA
    Guide at “J” da 0.89 mm
    Tunneller in stainless steel
    Standard Kit of content
    Chamber
    Catheter
    Connector
    Huber’s needle 22GA x 25.4 mm
    Luer’s connector

    Venous introduction set

    Code Colour Code
    201.51.10.21 Introduction Set 6.5 FR
    10
    201.51.10.31 Introduction Set 9 FR
    10
    • Introducer-dilator peel-away
    • Introducer needle from 18 GA
    • Guide at “J” da 0.89 mm
    • Tunneling in stainless steel
WhatsApp
Serve aiuto?
Buongiorno,
avete bisogno di aiuto ?