• Low profile plastic chamber, also suitable for patients with the same subcutaneous adipose tissue
    • Lightweight and affordable
    • Internal chamber in Titanium to prevent the needle from affecting the bottom and to ensure the absence of interaction with the infused substances
    • the large surface of the septum facilitates localization during skin palpation and reduces the risk of close punctures
    • transparent and radiopaque elastomeric connector: fast, safe and reversible connection of the catheter

    Caratteristiche

    Chamber
    Material Titanio + Polisulfone
    Shape and sizes: circular – diam. base. 27 mm
    Height: 10.6 mm
    Weight: 5.9 g
    Interior Volume : 0.36 ml

    Catetere con punta arrotondata, marcatura con punto ogni centimetro e numero ogni 5 centimetri.

    Septum
    Material Silicone
    Diameter available for punctures: 13 mm
    Maximum number of stings: 2000 with Huber needle of 22GA
    1000 with Huber  needle of 19GA
    Code
    Product
    description
    POWER TI
    Height
    mm
    Weight
    g
    Material
    ID
    mm
    OD
    mm
    Size
    Fr
    Lenght
    mm
    Introducer
    Dimension
    Fr
    Flow
    mL/min
    22GA
    Flow
    mL/min
    19GA
    201.22.12.21
    All-in-One
    10.6
    5.9
    silicone
    1.00
    2.10
    6,5
    780
    6.5
    7
    12
    201.22.12.31
    All-in-One
    10.6
    5.9
    silicone
    1.50
    2.70
    8
    780
    9
    10
    18
    201.22.12.41
    All-in-One
    10.6
    5.9
    PUR
    1.10
    1.70
    5
    780
    5
    8
    13
    201.22.12.20
    All-in-One
    10.6
    5.9
    PUR
    1.30
    2.00
    6,5
    780
    6.5
    7
    21
    201.22.12.33
    All-in-One
    10.6
    5.9
    PUR
    1.60
    2.70
    8
    780
    9
    8
    24
    201.22.10.21
    Standard
    10.6
    5.9
    silicone
    1.00
    2.10
    6,5
    780
    NA
    7
    12
    201.22.10.31
    Standard
    10.6
    5.9
    silicone
    1.50
    2.70
    8
    780
    NA
    10
    18
    201.22.10.41
    Standard
    10.6
    5.9
    PUR
    1.10
    1.70
    5
    780
    NA
    8
    13
    All-in-One Contents of Kit
    Chamber
    Catheter
    Connector
    Huber needle 22GA x 25.4 mm
    Luer connector
    Introducer-dilator peel-away
    Introducer needle from 18GA
    Guide to”J” of 0.89 mm
    Tunneler in stainless steel
    Standard Content of Kit
    Chamber
    Catheter
    Connector
    Huber needle of 22GA x 25.4 mm
    Luer Connector
    Venous introduction set
    Code Colour Code
    201.51.10.21 introduction set 6.5 FR
    10
    201.51.10.31 introduction set 9 FR
    10
    201.51.10.41 introduction set 5 FR
    10
    • Peel-away introducer-dilator
    • Introducer needle from 18 GA
    • Guide to “J” da 0.89 mm
    • Tunneling in stainless steel
  • INFUSION SYSTEMS


    Venous catheters ad
    Peripheral Access

    Healthmid

    HEALTHMID® is a peripheral venous catheter for short or medium term use. It allows the intravenous administration of fluids and drugs compatible with such peripheral positioning.
    It can also be used for high pressure contrast media infusions.
    It is not a Central Catheter so the insertion procedure is easier and faster than that of a PICC as it does not require verification of tip positioning. Not being a central catheter, it is not suitable for the infusion of drugs and substances that exclusively require this type of access such as substances with osmolarity & gt; 800 mOsm / l, pH & lt; 5 and pH & gt; 9, endothelium blistering and irritating drugs.

    Codice Lume Diametro
    Catetere
    Materiale
    Catetere
    Lunghezza
    totale
    Flusso
    Flow Rate
    Reverse
    Taper
    Marcatura
    Catetere
    CODES – HEALTHMID® WITH REVERSE TAPERING LENGHT 25 CM
    201.62.10.13 Single 3FR Polyurethane 250mm 2ml/s
    201.62.10.14 Single 4FR Polyurethane 250mm 5ml/s
    201.62.10.15 Single 5FR Polyurethane 250mm 7ml/s
    201.62.10.24 Double 4FR Polyurethane 250mm 2ml/s
    201.62.10.25 Double 5FR Polyurethane 250mm 5ml/s
    CODICI – HEALTHMID® CON REVERSE TAPERING LUNGHEZZA 25 CM
    201.62.12.13 Single 3FR Polyurethane 250mm 2ml/s
    201.62.12.14 Single 4FR Polyurethane 250mm 5ml/s
    201.62.12.15 Single 5FR Polyurethane 250mm 7ml/s
    201.62.12.24 Double 4FR Polyurethane 250mm 2ml/s
    201.62.12.25 Double 5FR Polyurethane 250mm 5ml/s
    CODICI – HEALTHMID® SENZA REVERSE TAPERING LUNGHEZZA 25 CM
    201.67.12.13 Single 3FR Polyurethane 250mm 2ml/s No
    201.67.12.14 Single 4FR Polyurethane 250mm 5ml/s No
    201.67.12.15 Single 5FR Polyurethane 250mm 7ml/s No
    201.67.12.24 Double 4FR Polyurethane 250mm 2ml/s No
    201.67.12.25 Double 5FR Polyurethane 250mm 5ml/s No
    CODICI – HEALTHMID® SENZA REVERSE TAPERING CON MANDRINO LUNGHEZZA 25 CM
    201.67.22.13 Single 3FR Polyurethane 250mm 2ml/s No
    201.67.22.14 Single 4FR Polyurethane 250mm 5ml/s No
    201.67.22.15 Single 5FR Polyurethane 250mm 7ml/s No
    201.67.22.24 Double 4FR Polyurethane 250mm 2ml/s No
    201.67.22.25 Double 5FR Polyurethane 250mm 5ml/s No
    CODICI – HEALTHMID® SENZA REVERSE TAPERING CON MANDRINO LUNGHEZZA 20 CM
    201.67.42.13 Single 3FR Polyurethane 200mm 2ml/s No
    201.67.42.14 Single 4FR Polyurethane 200mm 5ml/s No
    201.67.42.15 Single 5FR Polyurethane 200mm 7ml/s No
    201.67.42.24 Double 4FR Polyurethane 200mm 2ml/s No
    201.67.42.25 Double 5FR Polyurethane 200mm 5ml/s No
    CODICI – HEALTHMID® SENZA REVERSE TAPERING SENZA MANDRINO LUNGHEZZA 20 CM
    201.67.32.13 Single 3FR Polyurethane 200mm 2ml/s No
    201.67.32.14 Single 4FR Polyurethane 200mm 5ml/s No
    201.67.32.15 Single 5FR Polyurethane 200mm 7ml/s No
    201.67.32.24 Double 4FR Polyurethane 200mm 2ml/s No
    201.67.32.25 Double 5FR Polyurethane 200mm 5ml/s No

    INSTRUCTIONS FOR USE

    PACKAGING

    Box: 5 units
    Unit: a rigid blister sealed with Tyvek foil (first sterile barrier) contained within a medical paper pouch (second sterile barrier).

  • GAVeCeLT 2021 recommendations for the indication, implantation and management of venous access devices.
    Curated by Mauro Pittiruti and Giancarlo Scoppettuolo
    Raccomandazioni GAVeCeLT 2021
  • ACCESSOIRES POLYSWAB SWAB CAPS
    Disinfectant caps for catheter maintenance

    14280-14282

    Disinfectant cap

    • Provides instant and efficient active disinfection
    • Compatible with all needle-free access and luer systems
    • Eliminates personal compliance variations of the scrub the hub disinfection method and saves scrubbing time.
    • Ergonomic design for easy use
    • PVC-free, lactive-free, DEHP-free
    • Sterile range
    • Available in single pack and multipack
    • Available options:
      – 70% isopropyl alcohol
      -70% isopropyl alcohol + 2% chlorhexidine

    Code

    Product description


    90309

    disinfectant cap

  • ACCESSORI AGHI DI HUBER ago no coring per infusione

    14280-14282

    • Compatible with fully implantable Port systems
    • Compatible with fully implantable Port systems
    • Safety mechanism for protection from accidental punctures
    • Extension without PVC
    • Soft wings for easy handling and handling
    • Clamp to stop infusion as needed
    • Optional Y site without needle for drug intermediates
    • Size: 19G, 20G, 22G
    • est. Lenght of tube: 190 mm
    • Lenght of needle: 15 mm, 20 mm, 25 mm, 32 mm, 38 mm

    Code

    Item description


    201.11.59.11

    201.11.59.12

    201.11.59.13

    201.11.59.14

    201.11.59.21

    201.11.59.22

    Huber needle STD 19Ga 19mm with extension

    Huber needle STD 19Ga 25mm with extension

    Huber needle STD 19Ga 30mm with extension

    Huber needle STD 19Ga 37mm with extension

    Huber needle STD 20Ga 19mm with extension

    Huber needle STD 20Ga 25mm with extension

  • Catheter Mount

    Catheter Mount

    20180

    •  Suitable for connection between endotracheal tube and breathing circuits
    •  Provided with 22 mm standard female connector compatible with all breathing & ventilator circuit
    •  An elbow port is provided for easy suctioning without causing disturbance to breathing circuits
    •  I.D. 15 mm / O.D. 22 mm
  • HME Filter

    PolyFlush

    20424

    •  Filter Particles
    •  Moisture return: 32mg H2 O/L
    •  Flow rate: 30L minute at pressure 0.2Mpa
    •  Filter Efficiency: Greater than 95%
    •  Minimum tidal Volume: 150ml
  • Endotracheal Tube (Cuffed)

    20150-20916

    Autofusion Set


    Endotracheal Tube (Plain)

    20932-20939

    Novofusion Set

    •  Provided with soft cuff based on high volume and low pressure at the distal end
    •  Non-return valve with pilot cuff for easy assessment of the pressure in the main cuff
    •  Made of special thermo sensitive material readily conforming to body curvatures at body temperature

    Endotracheal tube sizes (I.D. of the tube in mm):

    Cuffed 3.5 4 4.5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10
    Plain 2 2.5 3 3.5 4 4.5 5 5.5

    Common Features

    •  Proximal end fitted with standard 15 mm connector
    •  Radiopaque line on the tube to facilitate easy location of tube
    •  Murphy eye at distal end for atraumatic intubation and extubation
  • Vial Access Spike
    Autofusion Set

    Polyspike

    Vial Access Spike

    13490-13496

    •  Vented spike for withdrawing fluids from vials or semi-rigid containers
    •  Reduces contamination through safety snap cap
    •  Available with green, blue & red color caps
    •  PVC free, DEHP free, Latex Free
    Polyspike Variants Fluid Filter Air Filter Nature of Use
    Polyspike R 0.1µ Chemotherapeutic Drugs
    Polyspike B 0.1µ Normal Drugs
    Polyspike G NA 0.1µ Normal Drugs
  • Technology Quick Flashback (Adva) I.V.

    Adva Quick Flashback Technology Needle Catheter

    • quick flashback that instantly confirms the success of venipuncture
    • needle technology improves first-time puncture success
    • instant confirmation of blood flow through the catheter body increases the likelihood of successful vein access

    I.V. photosensitive drug set

    14230

    • protects photosensitive drugs from UV rays, eliminating the harmful effects of light degradation
    • tubes with light protection
    • equipped with priming filter on luer lock support
    • latex free

    • the special Priming filter ensures the filling of the infusion line (auto priming) and keeps the line closed until it is connected to the patient
    • contributes to the reduction of hospital infections by reducing liquids subject to potential colonization
    • avoids the spillage of infusional liquids on the hands, floor or patient bed and avoids the waste of medication

    Available variants:

    available with rotating luer lock

    • with or without needle
    • available with rotating luer lock
    • with latex free Y injection point for intermittent infusions
    • with NFC Y connector
    Lenght
    (cm)
    Y-site
    Clamp
    Luer Lock
    rotante
    priming
    filter
    Code
    150 – DEHP Free
    N
    Orange
    Y
    Y
    14260
    180 – DEHP Free
    Y – Latex Free
    White
    Y
    Y
    14261
    180 – DEHP Free
    N
    Orange
    N
    N
    14263